Skip to main content

Persisted Meter Data

Overview​

Due to the dynamic way that meter totals are calculated with ACM, the ASSETMETER table for child assets will not persist an accurate LIFETODATE or SINCELAST% values.
The ASSETMETER table will only reflect the "direct" readings which have been entered against the child asset.
Any "indirect" readings, Ie. those readings inherited from a meter entry against a parent assembly are not recorded in the ASSETMETER table for a sub-assembly or child asset.

To provide an alternative to this an additional table is provided and automatically updated for configuration-managed assets:

PLUSAASSETTIMESINCE Table​

The PLUSAASSETTIMESINCE table records the current meter totals for a CM asset and its related CONTINUOUS type meters.

It is updated by the BDI whenever the asset is validated and as such should provide a near real time reflection of the current life information for the asset.

The PLUSAASSETTIMESINCE records are only updated by the BDI if the option: TSX is included with the list of "ACM Options" in the BDI Instance configuration.

The table contains the following attributes:

ParameterDescription
ASSETIDThe Asset identifier (ASSET.ASSETID).
ASSETNUMThe Asset number (ASSET.ASSETNUM).
SITEIDThe Site in which the asset resides (ASSET.SITEID).
METERNAMEThe continuous meter name.
LIFETODATEThe current meter total for asset.
SINCEINSTALLThe number of meter units accumlated since the last asset installation date.
SINCELASTREPAIRThe number of meter units accumlated since the asset was last repaired.
SINCELASTOVERHAULThe number of meter units accumlated since the asset was last overhauled.
SINCELASTINSPECTThe number of meter units accumlated since the asset was last inspected.