Continuous Meters for CM Assets

Overview​

Continuous Meters for configuration-managed (CM) assets operate in a different way to that of standard (non-cm) assets.
This section discusses this important distinction in depth as it is an often misunderstood area.

This topic is specific to Meters with a maximo meter type of CONTINUOUS. GAUGE and CHARACTERISTIC meters are treated and behave in the same way as standard Maximo Manage.

Explanation​

One of the key features of Maximo Aviation is its ability to dynamically calculate the life (meter totals) of an asset at any point over the course of its life.

Meter values can be derived and viewed for any point in time in the history of the assets life cycle. This "active life cycle accounting" provides improved compliance for regulated industries, while helping to increase reliability and accountability.

The life of an asset, at a specific "As of Date" is calculated dynamically (at run time) using a dedicated algorithm which considers:

  • The configuration history of an asset. Ie where it has been installed and between what dates.
    The information is recorded in the PLUSASAONOFF table.
  • The meter readings entered against the asset directly and also any at a higher level within the asset hierarchy (for the dates in which the asset was installed).
    These are recorded in the METERREADING table.
  • The Initial Reading Date and Initial Count. These are used to set an initial total for the meter at the date specified.
    This information is stored on the Asset Meter record in the fields: ASSETMETER.PLUSAANCHORDATE and ASSETMETER.PLUSAANCHORCOUNT.

This means that meter readings can be entered against any asset within a complex configuration managed structure and these readings will be automatically "inherited" by all sub-assembly (child) assets, depending on the configuration history.

The use of this dynamic meter calculation algorithm:

  • Negates the need for an Asset "Rolldown" to child assets and duplication of meter readings.
  • Means Any historical changes to the configuration of an asset or the creation, update or deletion of meter reading records will be immediately reflected on the asset and considered by associated maintenance plans when determining when they are next due.

Important Points​

It is important to ensure that the ASSETMETER.ROLLDOWNSOURCE is set to NONE for CM Assets. This should happen automatically for CM assets created through the application. Special care should be taken when loading datathrough the Maximo Integration Framework (MIF) that this is not value is not overridden.

Dute to the dynamic life algorithm, meter readings should not be loaded against parent and child assets, either through the UI or and integration. This will result in an incorrect calculation for child assets.